FAQs

If the DFE is, for example, 8-feet, does this mean that the elevation of the bottom portion of the lowest horizontal support member/ structure that supports the above living/ habitable area must be at least 8-feet? The 8-feet is not the top of the finished floor of the living / habitable area, correct?

Yes. The elevation must be referenced to the bottom of the lowest horizontal structural member if the structure is located in a V Zone or Coastal A Zone. If the structure is located outside of the V and Coastal A Zones, then the elevation can be referenced to the top of the floor.

2025-09-03T08:58:44-07:00September 3rd, 2025|

Can you please confirm that a garage floor/slab that is below the DFE must have breakaway walls on all sides of the enclosure area? Also, does this mean that the living/habitable area above the garage must be supported on piles, piers, or columns?

Confirmed. Breakaway walls are not a requirement on open foundations. A garage floor/slab below the BFE can remain open, be enclosed by insect screening or lattice work, or enclosed by breakaway walls. Also, since breakaway walls are not structural, the living area above the garage will have to be supported by structural piles/piers/columns.

2025-09-03T08:58:17-07:00September 3rd, 2025|

Can service utilities, machinery and equipment be physically attached to a breakaway wall inside the garage/ enclosure area?

No. Utilities, including electrical wiring, switches, outlets, breaker boxes, power meters, plumbing, conduits, and ventilation ducts, are not to be placed in or attached to breakaway wall panels. Building supply lines and other utility fixtures, such as light switches or electrical outlets, may be attached to the sheltered side of vertical foundation members as allowed

2025-09-03T08:55:22-07:00September 3rd, 2025|

What is temporary housing? Is this an option for me?

Temporary housing structures are defined as mobile homes, trailers, recreational vehicles or other structures which are self-contained units which include sanitary facilities, and facilities for normal daily routines including cooking and sleeping. Temporary housing structures DO NOT include any structure placed upon a permanent foundation, nor do they include tents, yurts, or similar fabric or

2025-08-26T10:55:37-07:00August 26th, 2025|

Are there Permit Exemptions for Exploratory Borings?

For the Broad, Franklin, and Palisades Fire rebuilds, geologic/geotechnical exploratory borings are exempt from requiring excavation permits.  This exemption was confirmed by the Building Official to help streamline the early stages of rebuilding.  

2025-08-26T10:54:26-07:00August 26th, 2025|

Will there be future rounds of this grant, and can I apply?

The Malibu City Council has not approved a second round of grants; however, the City is working closely with partner agencies such as Los Angeles County Supervisor Horvath, Los Angeles County Department of Economic Opportunity, Los Angeles County Economic Development Corporation (LAEDC), United States Small Business Administration and other local partners to bring additional resources

2025-07-31T08:55:37-07:00July 31st, 2025|